1-18 SPARC Enterprise Mx000 Servers XSCF User’s Guide December 2010
FIGURE 1-5 XSCF-LAN Redundancy (In Entry-level and Midrange Servers)
In the configuration examples shown in FIGURE 1-6, the XSCF-LANs are redundant and the
XSCF Unit is in a redundant configuration.
In the configuration with a single XSCF Unit, XSCF-LAN cannot be used by any XSCF Unit
failure even if the XSCF-LANs are redundant (duplicated). If one subnetwork is faulty, the
remaining path can be used (
FIGURE 1-6-c). If the active XSCF Unit is faulty, XSCF initiates
failover (
FIGURE 1-6-d). Therefore, high network availability can be achieved.
XSCF
System
Failure of
path or XSCF
a) No redundant LAN
XSCF
System
Failure of a path
b) Redundant LAN
Zobrazit stránku 33