Chapter 2 Setting Up XSCF 2-169
6. Use the showboards(8) command to discplay the XSB status again.
7. Use the poweron(8) command to start up all domains.
8. Use the showboards(8) command to confirm that the XSB has been added to
domain ID 1.
Note – When moving the system board to the domain by using the DR function that
operates the XSB without stopping the domain, see the Dynamic Reconfiguration Users
Guide.
XSCF> showboards –va
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 02(00) Assigned n n n Passed Normal n
01-0 01(00) Assigned n n n Passed Normal n
01-1 SP Available n n n Passed Normal n
01-2 02(09) Assigned n n n Passed Normal n
01-3 02(10) Assigned n n n Passed Normal n
XSCF> poweron –a
DomainIDs to power on:01,02
Continue? [y|n] :y
01 :Powering on
02 :Powering on
*Note*
This command only issues the instruction to power-on.
The result of the instruction can be checked by the
"showlogs power".
XSCF> showboards –va
XSB R DID(LSB) Assignment Pwr Conn Conf Test Fault COD
---- - -------- ----------- ---- ---- ---- ------- -------- ----
00-0 02(00) Assigned y y y Passed Normal n
01-0 01(00) Assigned y y y Passed Normal n
01-1 SP Available y n n Passed Normal n
01-2 02(09) Assigned y y y Passed Normal n
01-3 02(10) Assigned y y y Passed Normal n