Chapter 2 Setting Up XSCF 2-139
2. Use the setsnmpvacm(8) command to set VACM management information.
3. Use the showsnmpvacm(8) command to confirm the settings.
2.2.12 Mail Administration
The mail report function is used to send an email to the system administrator when the fault
has occurred in the system. This section explains how to set up the XSCF mail report
function.
Note – You should set up the mail configuration so the designated users (platadm, system
administrators, and so on) can receive immediate notification of faults that occur on the
platform or domain.
<Example 1> Add a user to an access control group xxxxx.
XSCF> setsnmpvacm creategroup -u yyyyy xxxxx
<Example 2> Delete a user from an access control group xxxxx.
XSCF> setsnmpvacm deletegroup -u yyyyy xxxxx
<Example 3> Create an MIB access control view without conditions.
XSCF> setsnmpvacm createview -s .1 all_view
<Example 4> Create an MIB access control view by using an OID mask.
XSCF> setsnmpvacm createview -s .1.3.6.1.2.1 -m fe excl_view
<Example 5> Delete an MIB access control view.
XSCF> setsnmpvacm deleteview -s .1.3.6.1.2.1 excl_view
<Example 6> Provide an MIB access control view to a group.
XSCF> setsnmpvacm createaccess -r all_view xxxxx
<Example 7> Delete a group from all MIB access control views.
XSCF> setsnmpvacm deleteaccess group1
XSCF> showsnmpvacm