Chapter 2 Setting Up XSCF 2-189
2.3 Save and Restore XSCF Configuration
Information
To save/restore the XSCF configuration information, execute the dumpconfig(8) and the
restoreconfig(8) command in the XSCF Shell. When the command is executed with
some options, all XSCF configuration information is saved at the specified location and is
restored from the specified location.
Note – The saving and restoring functions of the XSCF configuration by XSCF Shell
command are supported only on M3000/M4000/M5000/M8000/M9000 servers that run
certain versions of XCP firmware (beginning with XCP 1080). For specific information
about these minimum firmware requirements, see the latest version of the Product Notes (no
earlier than the XCP 1080 edition) for your server.
The XSCF configuration information can be saved in the device and can be restored using
one of the following two methods.
The configuration information can be saved and restored when a USB device has been
connected to the USB connector mounted on the XSCF Unit front panel of the
M4000/M5000/M8000/M9000 servers or rear panel of the M3000 server.
The configuration data is transmitted through the network with an encryption protocol.
Saving and Restoring Notes
The USB device should only be formatted using the FAT32 file system. Please ask
authorized service personnel about the USB capacity and the handling of USB devices.
You can restore the configuration information only to a system of the same model as
where the information was saved. For instance, the configuration information saved in the
M4000 server can be restored only to another M4000 server. The consistency of a current
system configuration file and a restored file are checked when data is restored. When it is
consistent with the configuration files, such as version, system name, the data can be
restored. In addition, the version of configuration files doesn't depend on XCP version.
Even if the XCP versions is the same when data is saved and restored, the versions of
each configuration file might be different.
In the M8000/M9000 server, the configuration information can be saved from either an
Active or Standby XSCF Unit. However, restoring can be done only to an Active XSCF
Unit.
The dumpconfig(8) command can encrypt saved data by specifying an option. You can
safely restore the encrypted data by performing the restoreconfig(8) command, then
input the specified key when saving.