Mains Connection
The mains supply is connected to a 3 way “Euro
Type” fused terminal block, which is fitted with a
315mA fuse. All electrical connections should be
carried out by a qualified electrician and must
comply with the current IEE regulations.
To comply with European regulations the
supply should be fed from a readily
accessible disconnect device, e.g.
un-switched fused spur fitted.
When making mains connections it should
be ensured that if the cable slips in such a
way as to place a strain on the conductors,
the protective earthing conductor will be
the last to take the strain.
Battery Connection
A 7Ah battery must be fitted to the system to allow
it to function during a mains fail condition. The
TS690 & TS690ID is equipped with a “Battery
Protection” circuit so that if a battery is accidentally
reverse connected or its voltage is below 4V, the
“BATT FAULT” LED lights. To clear the fault simply
reconnect or replace the battery as appropriate.
Remote Keypads
Four types of remote keypads can be used on the
system, however, only the NETLCD remote keypad
can be used for programming text information.
Any combination of remote keypad can be used
on the same system, if desired.
NETLCD Remote Keypad
The NETLCD remote keypad has a 32 character
backlit Liquid Crystal Display (LCD)
NETSTAR Remote Keypad
The NETSTAR remote keypad has a 8 character
backlit Starburst Liquid Crystal Display (LCD).
NETLED Remote Keypad
The NETLED remote keypad has a 4 character LED
display.
NETARM Remote Arming Station
The NETARM remote arming station does not have
a display, therefore it is designed to only be used
where setting, part setting and unsetting of the
system is required.
PCB Layouts & Connections
1 Detection Circuits.
Each remote keypad has two
programmable detection circuits.
2 Loudspeaker Volume.
For adjusting the volume of a speaker wired
to the remote keypad (NETLCD only).
3 LED Mimic.
If this jumper link is set to the “enabled”
position, the red () LED on the keypad will
be “ON” when the keypad output is active.
4 Remote I/D.
Used to select the remote keypads address.
(ENG = Engineer).
5 Ward Sounder Control.
This facility is not available for TS690 and
TS690ID systems.
6 Keys 1 and 3 PA Enable
Leave this link intact to enable PA alarm on
keys 1 and 3. When a user presses 1 and 3
together the control panel sounds a PA
alarm. Cutting the link ensures that when a
user presses keys 1 and 3, the control panel
reports an alarm from zone A on the keypad.
The alarm type will depend on how the zone
type is programmed in the control panel.
7 Loudspeaker Output.
This terminal can be connected to a single
16 Ohm Loudspeaker (NETLCD only).
12
System Installation TS690 & TS690ID Installation Manual
L
E
N
To transformer
FUSE 315mA
Figure 6. Mains Supply Connections