06 Bell Duration
This controls the duration of the external
bell/sounder. If the timer is set to 199 the bell
output is continuous. This timer has a working
range of 000-199 minutes. (Default: 020 Mins)
07 Bell Delay
This timer delays the activation of the external
bell/sounder and internal sounders. This timer
has a working range of 000-199 minutes. Note:
Any alarm during the entry procedure will
cancel the bell delay. (Default: 000 Mins)
08 2 Act. Time (Double Knock)
This is the “Double Knock” time window in which
either two circuit activation must occur within
this time to generate an alarm condition. Or
the circuit must remain active for the whole
duration of this time to generate an alarm
condition. This will only apply to circuits with the
“Double Knock” attribute. This timer has a
working range of 000-199 seconds. (Default:
008 Secs)
09 Test Time
This timer varies the number of days that “Test”
attribute may be applied to a circuit. If the
timer is set to 000 then circuits will remain on
test until the “Test” attribute is removed. This
timer has a working range of 000-030 days.
(Default: 014 Days)
10 2nd Entry
When the “Entry Timer” has expired the “2nd
Entry timer” starts to count down, if at the end of
this time the system or area has not been unset
then a full alarm will be generated. This timer
has a working range of 000-199 seconds.
(Default: 015 Secs)
11 P.Set Entry
This timer sets the entry period for the system
when the system is in the part-set condition. If
the timer is set to 000 the part-set entry timer is
the same as the main entry timer (timer 05). This
timer has a working range of 000-199 seconds.
(Default: 000 Secs)
12 Monitor Dur.
This timer affects the duration of the “Timed
Output” (No. 042). This timer has a working
range of 000-199 minutes. (Default: 000 Secs)
13 P.Set Bell Dly
This timer delays the activation of the external
bell/sounder and internal sounders when the
system is part set. Note that this timer operates
when alarm confirmation is disabled, and has
no effect when alarm confirmation is enabled.
This timer has a working range of 000-199
minutes. Note: Any alarm during the entry
procedure will cancel the bell delay. (Default:
000 Mins
14 Courtesy Dur.
This timer is used to control the duration of the
output type “Courtesy Light”. This timer has a
working range of 000-199 seconds. (Default:
030 Secs)
15 No. Rem. Resets
This counter determines how many coded
“Remote Resets” can occur before the system
locks into engineer reset only. Note: Remote
Reset by the "Rem Reset" input terminal is also
affected by this counter. This counter has a
working range of 000-199. (Default: 010)
16 Modem Rings
This counter is for use with the DC6, it allows the
installer to specify how many rings are required
before the DC6 picks up the call. If the counter
is set to 000 it will pick the call up as soon as any
incoming ringing is detected. This counter has
a working range of 000-199. (Default: 005)
17 P.I.D Alarms
When using the DC6 and "Contact ID
Extended Reporting". The number of Contact
ID alarms that are transmitted to the central
station per circuit are controlled by the value of
this counter. e.g., if the counter is set to 003
then all circuits will report 3 activation’s before
they are locked out from sending any more.
Note: this does not affect the re-arm of the
zone. This counter has a working range of 000 -
199. (Default: 005)
18 AC Off Dly
This timer delays the “audible” mains off
indication when the mains power is removed.
The display and any outputs programmed as
“Mains Off” are not affected. This timer has a
working range of 000-199 minutes. (Default:
000 Secs)
32
Engineer’s Menu 1 TS690 & TS690ID Installation Manual